Control panel, 9english controls and features (cont.) – JVC DLA-M20U Manuel d'utilisation

Page 10

Advertising
background image

9

ENGLISH

Controls and Features (cont.)

Control Panel

1

STAND BY Indicator
ON

: When in stand-by mode.

Blinking : When in cool-down mode.

Memo

About the cool-down mode:
This projector has a function to cool down the heated lamp for a fixed
period of time (approx. 120 seconds) after projection is finished. This
feature is referred to as the cool-down mode.

CAUTION

• The purpose of the cool-down mode is to prevent inner parts

from being deformed or broken by heat from the heated lamp
as well as to prolong the life of the lamp. Do not turn off the
main power switch while in the cool-down mode. Also, do
not place the projector on its side or stand it upright; this may
block the exhaust vents.

2

OPERATE indicator
ON:
When the projector is in operation (projecting)

3

OPERATE button
When the projector is in the stand-by mode, press this
button one second or more, and the main power switch is
turned on, causing the OPERATE indicator to light. Press
it one second or more again, and the projector goes into
the cool-down mode, then stand-by mode.

Memo

While in the cool-down mode:
If you press the OPERATE button, the projector is not turned on.

4

Lamp indicator
ON

: After the light-source lamp has been used for

more than approx. 900 hours.

Blinking : Replace the lamp. Refer to “Replacing the Light-

Source Lamp” on page 61.

5

TEMP indicator
ON:
The temperature inside the projector has abnormally

risen.

Note

• While the TEMP indicator is on (during abnormal temperature), the

power is automatically cut off, and an emergency mode is shown
(with the EMERGENCY indicator blinking).

6

EMERGENCY indicator
Blinking:
Something abnormal has occurred with the

projector.

Memo

About the emergency mode:
The emergency mode is shown when the following anomalies have
occurred with the projector (the EMERGENCY indicator blinks). In
the emergency mode, projection is automatically interrupted and the
cooling fans operate for about 20 seconds.
• When the air filter is displaced.
• When the filter is clogged.
• When the light-source lamp has suddenly gone off.
• When the fans have stopped.
• When the temperature inside has risen abnormally high.
• When the AC power supply is suddenly cut or interrupted.

CAUTION

• When an emergency mode is shown:

After the cooling fans have stopped, turn off the main power
switch and unplug the power cord from the wall outlet.
Make sure the lamp-replacement cover and the air filter are
correctly installed. Then, plug in the power cord again and
operate the projector.
If it goes into an emergency mode again, after the cooling
fans have stopped, turn off the main power switch, unplug
the power cord, and call your dealer for repair.

p