19

OPERATING INSTRUCTIONS

SHUTDOWN:

1. Move the switch to the "Pump" position.

2. Squeeze the trigger and discharge the water for a period of three minutes

to cool the heat exchanger and high pressure hose. (Insufficient cool down

period of the high pressure hose will cause excessive wear and eventual

rupturing of the hose.)

3. Move the switch to the "OFF" position. (Auto Start/Stop Option will shut

the unit down, but total shutdown requires switch to be moved to the

"OFF" position.)

4. Turn off the water supply and trigger the gun momentarily to relieve trapped

pressure.

5. Disconnect and drain the high pressure hose, gun, and dual lance. Wipe the

unit clean and store in a non-freezing environment.

STORAGE & MAINTENANCE INSTRUCTIONS

SPECIFIC MAINTENANCE:

PUMP: Change the pump oil after the first 50 hours of operation. After initial change,

every 3 months or 250 hour intervals are recommended. If oil appears dirty or

milky, changes may be required in greater frequency. Use pump oil SAE20 or

30 and fill only to the center of the oil sight glass. DO NOT overfill.

QUICK COUPLERS: There are o-ring seals inside the couplers which will deteriorate.

To replace, simply install a replacement o-ring to correct the leak. (Additional

o-rings can be purchased from your dealer.)

NOZZLE: Water flow through the spray nozzle will erode the orifice, making it

larger, resulting in a pressure loss. Nozzles should be replaced whenever

pressure is less than 85% of the maximum. The frequency of replacement will

depend upon such variables as mineral content in the water and number of

hours the nozzle is used.

FUEL WATER SEPARATOR: The fuel filter has a built in water separator.

Occasionally the water has to be drained from the separator. Follow the

procedures listed below:

1. Check the collection bowl daily.

2. Ensure the unit is off and place an oil catch basin under the

fuel cartridge.

3. Loosen the drain plug to allow the fuel/water contaminents to

flow into the catch basin.

4. Retighten the drain plug when completed.

5. Dispose of drainage according to environmental regulations in

your area.

BURNER AIR ADJUSTMENT: The air shutter has been factory preset for proper

operation between sea level and 2000 feet elevation at standard conditions

(60°F ambient water and air temperatures). To assure maximum combustion

efficiency at colder temperatures and higher altitudes, it will be necessary

to adjust the air supply to the combustion chamber. A smoke spot test is

recommended during any air shutter adjustment. This will aid in maximizing

the burner efficiency and avoid the inefficient operation and excessive

sooting of the combustion chamber.

1. The machine must be running and the burner on.

2. Take a smoke spot test to determine if more or less air is

required for proper combustion.

a. If the test is greater than a #3 smoke, turn the shutter

arm counterclockwise to increase the air flow into the

combustion chamber.

b. If the test is yellowish in color, turn the shutter arm

clockwise to decrease the air flow into the combustion

chamber.

3. Hold onto the air shutter adjusting arm and loosen the locking nut.

Move the shutter in 1/8" increments and retighten the locking nut

after each 1/8" movement.

4. Trigger the gun on and off slowly to make sure there is proper

ignition. Slight or no puffing on the ignition, and a smoke spot test

of 0-3 is good.

5. Repeat steps 2 and 3 until step 4 is attained.

LEAKS: Promptly eliminate any leaks found in the pumping system by removing

suspect parts, applying thread sealant to the threads and reinstalling.

NOTE: If using teflon tape, be certain no tape gets inside any plumbing to prevent

the possibility of a plugged spray nozzle.

DANGER

RISK OF INJECTION CAUSING

SEVERE INJURY!

-AUTO START/STOP FEATURE WILL

SHUTDOWN THE PRESSURE WASHER

UNTIL THE GUN IS TRIGGERED.

TOTAL SHUTDOWN REQUIRES "OFF/

PUMP/BURNER/STEAM" SWITCH TO

BE MOVED TO THE OFF POSITION.

-TO PREVENT ACCIDENTAL HIGH

PRESSURE DISCHARGE, DO NOT

LEAVE UNIT UNATTENDED UNTIL

"OFF/PUMP/BURNER/STEAM"

SWITCH IS IN THE OFF POSITION.