WATER SUPPLY:
1. Select a water supply hose which is a quality grade of garden hose measuring

at least 3/4" ID and no longer than 50 feet.

2. If your unit is equipped with a water strainer, ensure it is clean and free of

any obstructions. Periodic cleaning of the water strainer will help prevent

pump problems. As a strainer becomes obstructed, it restricts proper flow of

water to the pump. This can result in cavitation which will cause premature

failure of pump packings.

a. Unscrew the strainer bowl from the unit.
b. Remove strainer screen and clean or replace.

3. Connect one end of the water supply hose to the water inlet of the unit.

Connect the other end of the hose to your pressurized water supply.

NOTE: If there is a high mineral content in your water, it is recommended that

a water softener be used to prevent the possibility of excessive scale

buildup inside the heat exchanger coil.

4. Follow the incoming water requirements listed below:

a. Water pressure must be between a minimum of 20 pounds per square

inch (PSI) and a maximum of 125 PSI.

b. Incoming GPM must be approximately one gallon more than the outgoing

GPM stated on the pressure washer nameplate. (You can check GPM

by timing how long it takes to fill a 5 gallon container.)

c. Incoming water temperature must not exceed 125°F. Excessive pump

damage may result if the water temperature exceeds this acceptable

level.

5. Never allow the unit to operate without the incoming water line attached and

the water supply completely turned on.

INSTALLATION & PREPARATION

ADJUSTABLE PRESSURE DUAL LANCE:

This unit features an Adjustable Pressure Dual Lance which allows the user

to select a high or low pressure "fan" spray. Simply rotate the adjustable grip

on the dual lance to achieve the desired pressure selection.

1. Selection of high pressure can be achieved by turning the adjustable grip

on the Dual Lance assembly counterclockwise as shown in the figure

below.

2. Selection of low pressure can be achieved by turning the adjustable grip

on the Dual Lance clockwise as shown in the figure below.

DUAL LANCE CONNECTION:

1. Be certain the trigger gun is locked in the "OFF" position.

2. Connect the dual lance assembly to the trigger gun assembly at this time

(if applicable). Be certain the connection is securely tightened.

WARNING

RISK OF INJECTION CAUSING

SEVERE INJURY!

-THE TRIGGER GUN SHOULD

ALWAYS BE LOCKED IN THE OFF

POSITION WHEN NOT IN USE!

-NEVER LOOK DIRECTLY AT

THE NOZZLE UNLESS IT IS

DISCONNECTED FROM THE

TRIGGER GUN/DUAL LANCE

ASSEMBLY!

Advertising