Wet/Dry Vac Operator's Manual
TROUBLESHOOTING
SYMPTOM
PROBABLE CAUSE
REMEDY
Wet/Dry Vac will not start.
Power Cord is disconnected.
Ensure Power Cord is securely
connected to the unit and to the
power source. If using an
extension cord, ensure the power
cord and extension cord are
securely connected.
Circuit overload.
Check breaker or fuse panel.
Brushes on motor are worn.
Contact your Customer Service.
Inadequate suction.
Flexible Hose is obstructed, cut or
Clean or replace Flexible Hose.
damaged.
Wand or attachment is obstructed.
Clear obstruction.
Wet/Dry Filter is full of dirt.
Clean or replace.
No suction.
Canister is full.
Empty Canister.
SPECIFICATIONS
AC-9
TECHNICAL DATA
MODEL NO. AC-9
MOTOR
120V 2-Stage By-pass
HP
1.3 Nominal HP
CFM
101
WATERLIFT (Inches)
87
CAPACITY (Gallons)
9
WATER RECOVERY (Gallons)
6.0
ELECTRICAL CORD
25'
DIMENSIONS (L x W x H / Inches)
14 x 14 x 22
WEIGHT
25