OM-212 817 Page 16

3-10. Selecting 220 Volts AC Single/Three Phase Input Voltage

803 079 / 803 077

Y Turn Off welding power

source, and disconnect

input power before

proceeding.

Check input voltage available at

site.
1

Voltage Selection View

Window

The input voltage that the power

source is linked for appears in the

Voltage Selection View Window.
Check voltage selected in unit.

Changing selection is only

necessary if selected value does

not match available input voltage.
To change relinking board position,

remove top cover and left side

panel.
2

Relinking Board

3

Terminal Screws

Loosen terminal screws.
4

Relinking Board (Connection

For 220 VAC Single/Three

Phase Input Power)

Slide relinking board off connected

terminals, move relinking board to

correct input voltage terminals, and

secure relinking board.

1

Tools Needed:

5/16 in

2

4

3

.

Be sure to tighten all four screws
securing relinking board in place.