background image

OM-212 817 Page 14

3-7. TIG Lift-Arct DCEN (Direct Current Electrode Negative) Connections

Ref. 802 888 / Ref. 803 080

1

Positive (+) Weld Output

Terminal

Connect work lead to positive weld

output terminal.
2

Negative (−) Weld Output

Terminal

Connect TIG torch to negative weld

output terminal.
3

Gas Cylinder

4

Cylinder Valve

Open valve slightly so gas flow

blows dirt from valve. Close valve.
5

Regulator/Flowmeter

6

Flow Adjust

Typical flow rate is 15 cubic feet per

hour (7.1 liters per minute).
Connect torch gas hose to

regulator/flowmeter.
7

Gas Valve

Valve controls gas preflow and

postflow. Open valve on torch just

before welding.

2

Tools Needed:

1

3

4

11/16 in, 1-1/8 in, (21 mm)

5

7

6

Advertising