3-1. Specifications

Welding

Mode

Input

Power

Rated

Output

Welding

Amperage

Range

Maximum

Open-Circuit

Voltage

Amperes Input At Rated Load

Output, 50/60 Hz

KVA

KW

Dimensions

Net

Weight

Range

Voltage

220

400

440

KVA

KW

Dimensions

Weight

3-Phase

250 A @

30 VDC,

50 % Duty

Cycle

5-250 A

65 VDC

32.1

18.2

16.4

12.3

8.7

Stick

3-Phase

200 A @

28 VDC,

100 %

Duty Cycle

5-250 A

65 VDC

24.2

14.4

12.6

9.9

6.5

H: 13-1/2 in

(343 mm)

W: 7-1/2 in

40 lb

Stick

(SMAW)

1-Phase

200 A @

28 VDC,

50 % Duty

Cycle

5-200 A

65 VDC

42.6

n/a

n/a

10.0

6.6

W: 7 1/2 in

(191 mm)

D: 18 in (457

mm)

40 lb

(18.2 kg)

1-Phase

150 A @

26 VDC,

100 %

Duty Cycle

5-200 A

65 VDC

33.6

n/a

n/a

7.4

5.7

3-2. Duty Cycle And Overheating

Duty Cycle is percentage of 10

minutes that unit can weld at rated

load without overheating.
If unit overheats, output stops, and

cooling fan runs. Wait fifteen

minutes for unit to cool. Reduce

amperage or duty cycle before

welding.
Y Exceeding duty cycle can

damage unit and void

warranty.

200 A @ 50% Duty Cycle For Single Phase Operation

Overheating

0

15

A or V

OR

Reduce Duty Cycle

Minutes

250 A @ 50% Duty Cycle For 3 Phase Operation

5 Minutes Welding

5 Minutes Resting

5 Minutes Welding

5 Minutes Resting

206 173

Advertising