9

3. Connect ground wire (green or bare) of direct wire cable

to external ground conductor screw. Tighten screw.

4. Place the hooked ends of the other power supply cable wires

under the outer terminal block screws (hooks facing right).

Squeeze hooked ends together. Tighten screws.

5. Tighten strain relief screw.
6. Insert tab of terminal block cover into slot of dryer rear panel.

Secure cover with hold-down screw.

7. You have completed your electrical connection. Now go to

“Venting Requirements.”

3-wire connection: Power supply cord

Use where local codes permit connecting cabinet-ground

conductor to neutral wire.

1. Loosen or remove center silver-colored terminal block screw.
2. Connect neutral wire (white or center wire) of power supply

cord to the center silver-colored terminal screw of the terminal

block. Tighten screw.

3. Connect the other wires to outer terminal block screws.

Tighten screws.

4. Tighten strain relief screws.
5. Insert tab of terminal block cover into slot of dryer rear panel.

Secure cover with hold-down screw.

6. You have completed your electrical connection. Now go to

“Venting Requirements.”

3-wire connection: Direct Wire

Use where local codes permit connecting cabinet-ground

conductor to neutral wire.
Direct wire cable must have 5 ft (1.52 m) of extra length so

washer/dryer can be moved if needed.
Strip 3 " (89 mm) of outer covering from end of cable. Strip

insulation back 1" (25 mm) If using 3-wire cable with ground wire,

cut bare wire even with outer covering. Shape ends of wires into a

hook shape.

When connecting to the terminal block, place the hooked end of

the wire under the screw of the terminal block (hook facing right),

squeeze hooked end together, and tighten screw, as shown.

A. External ground conductor screw
B. Ground wire (green or bare) of power supply cord

C. Neutral ground wire
D. Center silver-colored terminal block screw

E. Neutral wire (white or center)
F. ¾" (19 mm) UL listed strain relief

A. 3-wire receptacle (NEMA type 10-30R)
B. 3-wire plug

C. Neutral prong
D. Spade terminals with upturned ends

E. " (19 mm) UL listed strain relief
F. Ring terminals

G. Neutral (white or center wire)

A

B

C

D

E

F

A

B

D

C

E

F

G

A. External ground conductor screw
B. Neutral ground wire

C. Center silver-colored terminal block screw
D. Neutral wire (white or center wire)

E. " (19 mm) UL listed strain relief

A

B

C

D

E

1"

(25 mm)

3 "

(89 mm)

3

4

3

4

1

2

1

2