8

1. Remove center silver-colored terminal block screw.
2. Remove neutral ground wire from external ground conductor

screw. Connect neutral ground wire and the neutral wire (white

or center wire) of power supply cord under center silver-

colored terminal block screw. Tighten screw.

3. Connect ground wire (green or bare) of power supply cord

to external ground conductor screw. Tighten screw.

4. Connect the other wires to outer terminal block screws.

Tighten screws.

5. Tighten strain relief screws.
6. Insert tab of terminal block cover into slot of dryer rear panel.

Secure cover with hold-down screw.

7. You have completed your electrical connection. Now go to

“Venting Requirements.”

4-wire connection: Direct Wire

IMPORTANT: A 4-wire connection is required for mobile homes

and where local codes do not permit the use of 3-wire

connections.
Direct wire cable must have 5 ft (1.52 m) of extra length so

washer/dryer can be moved if needed.
Strip 5" (127 mm) of outer covering from end of cable, leaving

bare ground wire at 5" (127 mm). Cut 1 " (38 mm) from

3 remaining wires. Strip insulation back 1" (25 mm). Shape ends

of wires into a hook shape.

When connecting to the terminal block, place the hooked end of

the wire under the screw of the terminal block (hook facing right),

squeeze hooked end together, and tighten screw, as shown.

1. Remove center silver-colored terminal block screw.
2. Remove neutral ground wire from external ground conductor

screw. Connect neutral ground wire and place the hooked end

(hook facing right) of the neutral wire (white or center wire) of

direct wire cable under the center screw of the terminal block.

Squeeze hooked ends together. Tighten screw.

A. Neutral ground wire
B. Center silver-colored terminal block screw

C. External ground conductor screw
D. Neutral wire (white or center)

E. " (19 mm) UL listed strain relief

A. External ground conductor screw
B. Ground wire (green or bare) of power supply cord

C. Neutral ground wire
D. Center silver-colored terminal block screw

E. Neutral wire (white or center)
F. ¾" (19 mm) UL listed strain relief

A

B

C

D

E

A

B

C

D

E

F

A. Neutral ground wire
B. Center silver-colored terminal block screw

C. External ground conductor screw
D. Neutral wire (white or center wire)

E

.

¾" (19 mm) UL listed strain relief

1"

(25 mm)

5"

(127 mm)

A

B

C

D

E

3

4

1

2