Miller Electric OM-842 Manuel d'utilisation

Page 49

Advertising
background image

OM-842 Page 45

0 Ohms

OL

A

B

C

Figure 7-1. Testing Energized User Relay

4.

If the relay is working correctly, the VOM reads the re-
sistances shown. In this case, go to Step 5.

If the VOM does not read the resistances shown while
the relay is energized, contact the nearest Factory Au-
thorized Service Station/Service Distributor.

5.

Press Parameter Select again to deenergize the relay.
The program automatically returns to the repeating test
displays.

6.

Use the VOM to check the resistance across the relay
terminals as shown in Figure 7-2.

A

B

C

0 Ohms

OL

Figure 7-2. Testing Deenergized User Relay

7.

If the relay is working correctly, the VOM reads the re-
sistances shown. In this case, go to Step 8.

If the VOM does not read the resistances shown while
the relay is deenergized, contact the nearest Factory
Authorized Service Station/Service Distributor.

8.

When the applicable user relay tests okay, use the
Right/Increase or Left/Decrease push button to access
another test, or stop the diagnostics program.

N. Remote Pendant Test

This procedure tests the operation of the push buttons on the
Remote Pendant.

1.

When the repeating test displays are shown (see Sec-
tion 7-2C), press Right/Increase or Left/Decrease until
the display shows:

R E M O T E

P E N D A N T

T E S T

2.

Press Parameter Select to begin the test. The display
shows:

P U S H

S T A R T / I N C

O N

R E M O T E

3.

When this display appears, the control unit waits three
seconds for the Start/Increase push button to be
pressed. If this is done in time and the push button is
working correctly, the display shows:

B U T T O N

I S

W O R K I N G

P R O P E R L Y

If the Start/Increase push button tests okay, go to Step
5.

4.

If the Start/Increase push button is not pressed in time,
or if the push button is not working correctly, the display
shows:

B U T T O N

I S

N O T

W O R K I N G

P R O P E R L Y

If the Start/Increase push button is not working correct-
ly, replace the push button.

5.

When the Start/Increase push button tests okay, press
Parameter Select. The display shows:

P U S H

D E C R E A S E

B U T T O N

O N

R E M O T E

6.

When this display appears, the control unit waits three
seconds for the Decrease push button to be pressed. If
this done in time and the push button is working cor-
rectly, the display shows:

B U T T O N

I S

W O R K I N G

P R O P E R L Y

If the Decrease push button tests okay, go to Step 8.