4. setting dip switch sw1 – Miller Electric OM-842 Manuel d'utilisation

Page 15

Advertising
background image

OM-842 Page 11

2-4.

Setting DIP Switch SW1

Ref. ST-800 194 / Ref. ST-162 477-A

Set DIP switch SW1 rocker switch
positions as follows:

1

Control Box Front Panel

2

Retaining Screw Location

Loosen retaining screw, and open
hinged front panel.

3

Microprocessor Board PC5

4

DIP Switch SW1

5

Positions 7 And 8

Set 7 and 8 according to table to se-
lect Semi-Automatic Modes 1 thru
5.

6

Position 4

Set Off to run diagnostics program.

Set On to stop diagnostics pro-
gram, and for all other operations.

7

Position 3

Use position 3 to select whether
pulses are defined as frequency or
time values.

Set Off to define as frequency.

Set On to define as time.

8

Positions 1 And 2

In Automatic and Semi-Automatic 1
modes, weld amperage can be ad-
justed up or down during weld using
remote pendant. Define amperage
adjustment range limits by setting
positions 1 and 2 according to table.

Close front panel and tighten retain-
ing screw after setting SW1.

1

On

On

Off

Off

On

Off

On

Off

Position

7

Position

8

Defined

Semi-Automatic

Mode

*1

2

3

4

*5

On

On

*Semi-Automatic 1 mode is defined when remote Stop
switch is connected. Semi-Automatic 5 mode is defined
when remote Stop switch is not connected.

2

4

3

Actual numbers 1 thru 8 below rocker
switches are upside down. Positions
5 and 6 are not used.

Tools Needed:

Position

On

On

Off

Off

On

Off

On

Off

±

5 Amperes

±

10 Amperes

±

20 Amperes

±

40 Amperes

1

Position

2

Defined

Amperage

Adjustment

Limit

1

2

3

4

5

6

7

8

4

8

5

6

7

= On

Rocker Switch Settings:

= Off