SECTION 2 – INSTALLATION

2-1.

Connecting Remote Pendant Or Equivalent User-Wired Control

A user-wired equivalent to the remote pendant may be connected to the control
unit. However, connections must be made for a Stop push button even if it is not
used in unit operation. Since the Stop button is wired in a normally closed
configuration, if Stop connections are not made, the control unit interprets that as
the Stop button being continually pressed. Refer to Figure 8-1 for a circuit diagram
of the remote pendant.

NOTE

sb7.1* 5/94 – Ref. ST-162 479-A / Ref. ST-146 839 / Ref. S-0446-A

1

Remote Pendant

2

Remote 4 Receptacle RC3
(See Section 2-2)

3

Keyway

4

Plug

5

Threaded Collar

Use receptacle to connect supplied
remote pendant. User-wired con-
trols equivalent to remote control
are also connected to this
receptacle.

To connect to receptacle, align key-
way, insert plug, and tighten
threaded collar.

D

A

C

B

1

4

5

2

3

2-2.

Remote 4 Socket Information

A

Normally closed contact with socket C, opens when pendant Stop button is pressed.

B

Normally open contact with socket C, closes when pendant Decrease button is pressed.

C

Circuit common.

D

Normally open contact with socket C, closes when pendant Start/Increase button is pressed.