Installation clearances, Recessed area, Mobile home - additional installation requirements – Maytag W10267631A-SP Manuel d'utilisation

Page 5: Mobile home installations require

Advertising
background image

5

Installation clearances

The location must be large enough to allow the dryer door

to open fully.

Dryer Dimensions

29"

(737 mm)

22

1

/

4

"

(565 mm)

29

1

/

4

"

(743 mm)

43

1

/

2

"

(1105 mm)

NOTE: Most installations require a minimum 5" (127 mm)
clearance behind the dryer for the exhaust vent with elbow.

See “Venting Requirements.”

Installation spacing for recessed area or closet installation

The following spacing dimensions are recommended for this dryer.
This dryer has been tested for spacing of 0" (0 mm) clearance on

the sides and rear. Recommended spacing should be considered

for the following reasons:

Additional spacing should be considered for ease of installation
and servicing.

Additional clearances might be required for wall, door, and floor
moldings.

Additional spacing should be considered on all sides of the dryer
to reduce noise transfer.

For closet installation, with a door, minimum ventilation openings
in the top and bottom of the door are required. Louvered doors
with equivalent ventilation openings are acceptable.

Companion appliance spacing should also be considered.

14" máx.*

(356 mm)

29"

(737 mm)

5"

(127 mm)

1"

(25 mm)

1"

(25 mm)

18"*

(457 mm)

3"*

(76 mm)

3"*

(76 mm)

29

1

/

4

"

(743 mm)

48"

2

*

(310 cm

2

)

24"

2

*

(155 cm

2

)

Recessed

area

Side view- closet

or confined area

Closet door

with vents

Mobile home - Additional installation requirements

This dryer is suitable for mobile home installations. The installation
must conform to the Manufactured Home Construction and Safety
Standard, Title 24 CFR, Part 3280 (formerly the Federal Standard

for Mobile Home Construction and Safety, Title 24, HUD Part 280)

or Standard CAN/CSA-Z240 MH.

Mobile home installations require:

All Dryers

Metal exhaust system hardware, which is available for purchase
from your dealer.

Special provisions must be made in mobile homes to introduce
outside air into dryer. The opening (such as a nearby window)
should be at least twice as large as the dryer exhaust opening.

For gas dryers

Mobile Home Installation Kit Part Number 346764. See “Tools
and Parts” section for information on ordering.

Advertising
Ce manuel est liée aux produits suivants: