Dryer gas pipe

The gas pipe that comes out through the rear of your dryer

has a 3/8" male pipe thread.

A. 1/2" NPT gas supply line
B. 3/8" NPT dryer pipe

A

B

*6¼"
(159 mm)

1½"
(38 mm)

*NOTE: If the dryer is mounted on a pedestal, the gas pipe

height must be an additional 10" (254 mm) or 15.5" (394 mm)
from the floor, depending on the pedestal model. For a garage
installation, the gas pipe height must be an additional
18" (460 mm) from the floor.

Make Gas Connection

1. Remove the red cap from the gas pipe.

2. Using a wrench to tighten, connect the gas supply to the dryer.

Use pipe-joint compound on the threads of all non-flared male
fittings. If flexible metal tubing is used, be sure there are no kinks.

A

B

A. Flared male fitting
B. Non-flared male fitting

NOTE: For LP gas connections, you must use pipe-joint
compound resistant to the action of LP gas. Do not use
TEFLON

®†

®TEFLON is a registered trademark of E.I. Du Pont De Nemours and Company.

tape.

A combination of pipe fittings must be used to connect the dryer
to the existing gas line. Shown is a recommended connection.
Your connection may be different, according to the supply line
type, size and location.

A. 3/8" flexible gas

connector

B 3/8" dryer pipe

C. 3/8" to 3/8" pipe elbow
D. 3/8" pipe-to-flare

adapter fitting

A

B

C

D

3. Open the shutoff valve in the supply line. The valve is open when

the handle is parallel to the gas pipe.

A. Closed valve
B. Open valve

A

B

4. Test all connections by brushing on an approved noncorrosive

leak-detection solution. Bubbles will show a leak. Correct any

leak found.

VENTING

Venting Requirements

WARNING

Fire Hazard

Use a heavy metal vent.

Do not use a plastic vent.

Do not use a metal foil vent.

Failure to follow these instructions can result in death
or fire.

WARNING:

To reduce the risk of fire, this dryer MUST BE

EXHAUSTED OUTDOORS.

IMPORTANT: Observe all governing codes and ordinances.

The dryer exhaust must not be connected into any gas vent,
chimney, wall, ceiling, attic, crawlspace, or a concealed space

of a building. Only rigid or flexible metal vent shall be used

for exhausting.

If using an existing vent system

Clean lint from the entire length of the system and make

sure exhaust hood is not plugged with lint.

Replace any plastic or metal foil vent with rigid or flexible

heavy metal vent.

Review vent system chart. Modify existing vent system

if necessary to achieve the best drying performance.