10

Optional exhaust installations.

Exhaust Cover Kit (to cover unused exhaust holes):

Part Number W10186596 - all models

This dryer can be converted to exhaust out the right side, left side

or through the bottom. If you prefer, you may contact your local
dealer to have the dryer converted.

A

B

C

A. Standard rear offset exhaust installation
B. Left or right side exhaust installation

C. Bottom exhaust installation

Alternate installations for close clearances

Venting systems come in many varieties. Select the type best

for your installation. Two close-clearance installations are shown.
Refer to the manufacturer’s instructions.

A B

A. Over-the-top installation (also available with one offset elbow)
B. Periscope installation

NOTE: The following kits for close clearance alternate installations
are available for purchase. Please see the “Assistance or Service”
section in your Use and Care Guide to order.

Over-the-Top Installation:

Part Number 4396028

Periscope Installation (For use with dryer vent to wall vent
mismatch):

Part Number 4396037 - 0" (0 mm) to 18" (460 mm) mismatch

Part Number 4396011 - 18" (460 mm) to 29"(737 mm) mismatch

Part Number 4396014 - 29" (737 mm) to 50" (1270 mm)
mismatch

Special provisions for mobile home installations

The exhaust vent must be securely fastened to a noncombustible
portion of the mobile home structure and must not terminate
beneath the mobile home. Terminate the exhaust vent outside.

Determine vent path

Select the route that will provide the straightest and most direct
path outdoors.

Plan the installation to use the fewest number of elbows

and turns.

When using elbows or making turns, allow as much room

as possible.

Bend vent gradually to avoid kinking.

Use the fewest 90° turns possible.

Determine vent length and elbows needed for best
drying performance

Use the following vent system chart to determine type of vent
material and hood combinations acceptable to use.

NOTE: Do not use vent runs longer than those specified

in the Vent system chart.

Exhaust systems longer than those specified will:

Shorten the life of the dryer.

Reduce performance, resulting in longer drying times

and increased energy usage.

The vent system chart provides venting requirements that will help
to achieve the best drying performance.

Vent system chart

NOTE: Side and bottom exhaust installations have a 90º turn inside
the dryer. To determine maximum exhaust length, add one 90º turn
to the chart.

Number

90º elbows

Type of vent

Box /Louvered

hoods

Angled
hoods

0

Rigid metal

64 ft. (20 m)

58ft. (17.7 m)

1

Rigid metal

54 ft. (16.5 m)

48 ft. (14.6 m)

2

Rigid metal

44 ft. (13.4 m)

38 ft. (11.6 m)

3

Rigid metal

35 ft. (10.7 m)

29 ft. (8.8 m)

4

Rigid metal

27 ft. (8.2 m)

21 ft. (6.4 m)

Advertising