45° elbows provide better airflow than 90° elbows, Good, Better – Maytag W10267631A-SP Manuel d'utilisation

Page 9: Plan vent system

Advertising
background image

9

If this is a new vent system

Vent material

Use a heavy metal vent. Do not use plastic or metal foil vent.

4" (102 mm) heavy metal exhaust vent and clamps must

be used.

4" (102 mm) heavy metal exhaust vent

4"

102 mm

Vent products can be purchased from your dealer or by calling
Whirlpool Service. For more information, see the “Assistance

or Service” section in your Use and Care Guide.

Rigid metal vent

For best drying performance, rigid metal vents

are recommended.

Rigid metal vent is recommended to avoid crushing and kinking.

Flexible metal vent

Flexible metal vents are acceptable only if accessible

for cleaning.

Flexible metal vent must be fully extended and supported

when the dryer is in its final location.

Remove excess flexible metal vent to avoid sagging and kinking
that may result in reduced airflow and poor performance.

Do not install flexible metal vent in enclosed walls, ceilings,

or floors.

The total length of flexible metal vent should not exceed

7¾ ft. (2.4 m).

Elbows

45° elbows provide better airflow than 90° elbows.

Good

Better

Clamps

Use clamps to seal all joints.

Exhaust vent must not be connected or secured with screws

or other fastening devices that extend into the interior

of the duct and catch lint. Do not use duct tape.

Clamp

Exhaust

A and B: Recommended hood styles.

C: Acceptable hood style.

4"
(102 mm)

4"
(102 mm)

B

A

4"

(102 mm)

2½"

(64 mm)

C

A. Louvered hood style
B. Box hood style

C. Angled hood style

An exhaust hood should cap the vent to keep rodents

and insects from entering the home.

Exhaust hood must be at least 12" (305 mm) from the ground

or any object that may be in the path of the exhaust (such

as flowers, rocks or bushes, snow line, etc.).

Do not use an exhaust hood with a magnetic latch.

Improper venting can cause moisture and lint to collect
indoors, which may result in:

Moisture damage to woodwork, furniture, paint, wallpaper,
carpets, etc.

Housecleaning problems and health problems.

Plan Vent System

Choose your exhaust installation type

Recommended exhaust installations

Typical installations vent the dryer from the rear of the dryer. Other
installations are possible.

A

B

B

C

D

E

F

G

H

A. Dryer
B. Elbow

C. Wall
D. Exhaust hood

E. Clamps

F. Rigid metal or flexible metal vent

G. Vent length necessary to connect elbows
H. Exhaust outlet

Advertising