Eagle Pump & Compressor Portable Electric/Gas Compressor Manuel d'utilisation

Page 9

Advertising
background image

7

B) ELECTRIC DRIVE WITH DUAL CONTROL

1) Check unit for any damage.
2) Check compressor oil level, fill or add if necessary.
3) Pressure switch "Off/Auto" knob should be in "Off" position.
4) Plug in power cord to proper electrical outlet.
5 a) Stop/Start (pressure switch) control

1. Shut-off valve on pilot unloader should be closed ("knurled"

knob on top of the pilot unloader should be turned all the way
down).

2. Turn pressure switch "Off/Auto" switch to "Auto". Electric

motor should now start and fill air receiver(s) with compressed
air till cut-out pressure is reached. Compressor should stop
and remain stopped till air receiver pressure reaches the cut-in
pressure. The unit will continue to cycle in this automatic
operation until it is turned off.

b) Continuous run (Pilot unloader) control

1. Open the shut-off valve on pilot unloader ("knurled" knob on

top of the pilot unloader should be turned all the way up).

2. Turn pressure switch "Off/Auto" switch to "Auto", electric motor

should now start and fill air receiver(s) with compressed air till
full pressure is reached. To engage continous run, turn “knurled
knob down. Your compressor will idle down and continue to
idle once maximum pressure is acheived. When cut-in pressure
is reached, the unloader valves will de-activate and unit will
compress air. The unit will continue in this automatic operation
until the unit is stopped ("Off/Auto" switch turn to the "Off"
position and/or electric power supply is disconnected).

3. With the engine running properly, the compressor fills the air

receiver with compressed air, when maximum pressure (set
by the pilot valve control) is reached, the engine and
compressor will slow down to idle speed, and will return to
full RPM when the cut-in pressure is reached. The unit will
continue to cycle automatically until turned off.

4. Stopping the engine.

a) Turn engine switch to the "Off" position.
b) Turn the fuel lever to the "Off" position.

6) You can switch at anytime from Stop/Start to Continuous Run and

vice versa by opening or closing the valve on the pilot unloader.

C) ELECTRIC DRIVE

1) Check unit for any damage.
2) Check compressor oil level, fill or add if necessary.
3) Pressure switch "Off/Auto" switch should be in "Off" position.
4) Plug in power cord to proper electrical outlet. If compressor is

not equipped with a male plug, hire an electrician to install one.

Advertising