Trouble shooting – Eagle Pump & Compressor Portable Electric/Gas Compressor Manuel d'utilisation

Page 11

Advertising
background image

Will Not
Start

Low
Pressure

Oil In
Discharge

Compresso
r Overheats

Compresso
r Loads and
Unloads or
Stops and
Starts
Excessively

• Check power supply

• Please refer to Honda

manual included

• Safety valve leaks
• Drain cock open
• Loose tubes or fittings
• Dirty or plugged air filter

• Defective unloader valve

• Improper oil viscosity
• Too much oil in the

crankcase

• Compressor overheated

• Restricted air filter
• Worn piston rings

• Clogged inlet filter

• Dirty compressor, head,

cylinder, intercooler

• Operating pressure too high
• Low oil or wrong oil being

used

• Compressor cycle too long,

proper cycle is 50 - 60% on
Stop/Start operation and 75
- 80% on continuous run
operation

• Leaks in air system

• Worn or loose drive belts
• Pilot valve or pressure switch

differential adjusted too
close

• Defective compressor valves
• Compressor too small for

intended use

• Make sure power is turned

on

• Please refer to Honda

manual included

• Replace safety valve
• Close drain cock
• Tighten fittings
• Clean or replace as

necessary

• Replace unloader valve

• Drain and replace oil
• Drain oil and fill to proper

level

• Air pressure regulated too

high

• Clean or replace air filter
• Replace piston rings

• Clean or replace as

necessary

• Clean with compressed air

• Reduce operating pressure
• Drain and replace oil

• Allow for longer rest

between cycles

• Replace worn components

as necessary

• Tighten V-belts or replace
• Make necessary

adjustments

• Replace valves

TROUBLE SHOOTING

PROBLEM

POSSIBLE CAUSE

CORRECTIVE ACTION

9

Advertising