What to do before calling for service:

Reasons the machine might shut itself off:
• Lack of water.
• Freeze cycle takes too long.
• Harvest cycle takes too long.
• High discharge pressure.
• Ice level control set wrong
Check the following:

1. Has the water supply to the ice machine or building been shut off? If yes, the ice machine will automatically

restart within 25 minutes after water begins to flow to it.

2. Has power been shut off to the ice machine? If yes, the ice machine will automatically restart when power

is restored.

3. Is the curtain open because some ice is stuck under it? If so, remove the ice and the machine should start

in a few minutes.

4. Check the adjustment knob of the ice level control. See page 21.

Note: Curtain can be removed & replaced anytime the machine is in a standby mode or when it is in a freeze

cycle. However, removal of the curtain during freeze will result in water flowing into the bin. Removal of the

curtain during harvest terminates harvest at that point and, if left off, will result in the machine shutting off.

To Manually Reset the machine.

1. Open the switch door.

2. Push and release the Off button.

3. Push and release the On button.

To Shut the Machine Off:

1. Push and hold the Off button for 3 seconds

or until the machine stops.