Installation, Introduction continued – Garland G2000 SERIES GAS BAKE AND ROAST DECK OVENS Manuel d'utilisation

Page 6

Advertising
background image

Part # P125 Rev 2 (07/31/12)

Page 6

Pre-Installation Instructions

The importance of proper installation of commercial

gas cooking equipment cannot be over stressed. Proper

performance of the equipment is dependent, in great part,

on the compliance of the installation with the manufacturer’s

specifications. The installation and connections must comply

with local codes, or in the absence of local codes, with

CAN/CGA-B149 installation code or with the National Fuel

Gas code, ANSI Z 223.1/NFPA No. 54 – latest edition.

All burner adjustments and setting shall be made by a

qualified gas technician.

A. The type of gas for which the unit is equipped is stamp on

the date plate located behind lower front panel. Connect

a unit stamped “NAT” only to natural gas; connect a unit

stamped “PRO” only to propane gas.

B. If it is a new installation, have gas authorities check meter

size and piping to assure that the unit is supplied with

sufficient amount of gas pressure required to operate the

unit.

C. If it is additional or replacement equipment, have gas

authorities check pressure to make certain that existing

meter and piping will supply fuel at the unit with not

more than 1/2” water column pressure drop.

INSTALLATION

Rating Plate

When corresponding with the factory or your local

authorized factory service center regarding service problems

or replacement parts, be sure to refer to the particular unit

by the correct model number (including the prefix and suffix

letters and numbers) and the warranty serial number. The

rating plate affixed to the unit contains this information.

We suggest installation, maintenance and repairs should be

performed by your local authorized service agency listed in

your information manual pamphlet.

In the event you have any questions concerning the

installation, use, care or service of the product, write or call

our Product Service Department.

This product must be installed by professional personnel as

specified. Garland/U.S. Range products are not approved or

authorized for home or residential use, but are intended for

commercial applications only. Garland / U.S. Range will not

provide service, warranty, maintenance or support of any

kind other than in commercial applications.

Location of the Oven

Appliances shall be installed in a location in which the

facilities for ventilation permit satisfactory combustion of gas

and proper venting. Appliances shall be located so as not to

interfere with proper circulation of air within the confined

space. When buildings are so tight that normal infiltration

does not provide the necessary air, outside air shall be

introduced.

Clearances

NOTE: Unit must be installed with no less than

6 inches (152mm) clearance from combustible construction

at both sides and rear. Installation to non-combustible

construction is (0”) clearance at both sides and rear. The unit

suitable for installation on combustible floors.