GENERAL INSTALLATION

Unpacking

Carefully remove units from cartons. Remove all packing

materials from units. The protective material covering the

stainless steel should be removed immediately after the unit

is installed.

Serial Plate

All electrical ratings are shown on the serial plate of each

unit and are readily visible by opening the enameled door

located below the control panel.

Ensure electrical supply conforms with electrical

characteristics shown on the rating plate.

Statutory Regulations

The installation and connection should comply with current

codes in Canada – The Canadian Electrical Code Part 1

and / or local codes. In USA – The National Electrical Code

ANSI / NFPA – Current Edition.

Ventilation requirements can vary by country, state or

providence, please consult with local authorities having

jurisdiction for code requirements.

Installation Of Banking Plates

All units may be installed independently or banked with

other ED or GD series equipment. To ensure a matching

and permanent fit between units, two banking plates are

available for each unit to be installed. One at the front and

one at the rear of each two units being banked together. If

optional 2 1/2” (64mm) legs are supplied with unit, discard

leveling bolts and replace with legs.

1. Level each unit by adjustment of leveling bolts or legs.

Use a spirit level and level unit four ways; across front and

back and down left and right edges. Level all other units

to the first unit.

NOTE: Griddles may not rest evenly on the unit body if units

are not leveled.

2. Remove acorn nuts at rear of unit.

3. Attach one banking plate in position at rear by placing 1/4”

(6mm) diameter holes in the banking plate over the screw

holes in the rear of units and fasten by replacing the acorn

nuts removed in step 2.

4. Push units into position on counter top or back bar.

5. To secure the front, open the lower front panel, place

banking plate over the two holes (one on each unit) and

secure banking plate using sheet metal screws supplied.

REAR VIEW

FRONT VIEW

Sanitary Countertop Seal

When appliance is installed without legs on a counter top, it

must be sealed in accordance with N.S.F. standards as per the

following instructions:

1. Appliance should be located on a level counter top

surface. Complete the electrical connection.

2. Thoroughly clean the appliance bottom perimeter and

the counter top area around the appliance perimeter.

3. Lay a generous bead of silicone under the entire

perimeter of appliance bottom.