Page 10

Broilers – Models: ED-15B,

ED-30B & ED-42B
Wall Clearance

Do not install appliance closer to a wall of combustible

material than:

Back 9” (229mm)

Sides 9” (229mm)

Supply Connection

For supply connection, use wire suitable for 90°C (194°F).

Electrical Connection

A knockout is provided near the front left side of the unit

located behind the control panel. To view knockout, loosen

the two acorn nuts and hinge control panel downward. The

terminal block is also located in this area.

The cable entrance is located on the right side when facing

the rear of the unit. The cable is fed towards the front

through a wire way.

Controls

Infinite switches are used to control the elements.

HI to 5 -

High heat

5 to 3

-

Medium Heat

3 to LO -

Low Heat

Setting of switches between the numbers will give

intermediate heat. Switches are reversible and may be

turned right or left.

Food Warmers – Models ED-15W & ED-15WP
Wall Clearances

Do not install appliance closer to a wall of combustible

material than:

Back 1” (25mm)

Sides 1” (25mm)

Supply Connection

NOTE: Applicable to Model ED-15W only. Model

ED-15WP is a 115 volt unit supplied with a grounded cord

and plug.

For Model ED-15W, use a wire suitable for 90°C (194°F).

Electrical Connection

NOTE: Applicable to Model ED-15W only.

A knockout is provided near the front left side of the unit

located behind the control panel. To view knockout, loosen

the two acorn nuts and hinge control panel downward. The

terminal block is also located in this area.

The supply cable entrance is located on the right side when

facing the rear of the unit. The cable is fed towards the front

through a wire way.

Controls

Infinite switches are used to control the elements.

HI to 5 -

High Heat

5 to 3

-

Medium Heat

3 to LO -

Low Heat

Setting of switches between the numbers will give

intermediate heat. Switches are reversible and may be

turned right or left.

Operating Instructions

ED series food warmers are supplied with a removable tank

assembly. Fill tank with 1-1/4” (32mm) to 1-1/2” (38,mm) of

water.

While not supplied with the food warmer it uses a 200

series of Gastronorm cafeteria pan and any arrangement

of 200 series pans in various sizes may be used. Individual

preference of the operation will determine sizes of inserts

to be used. Pans may be purchased from your kitchen

equipment dealer.

CAUTION: Do Not Allow The Tank Assembly To Run Dry.

ED Series food warmers are wet type only. Operating these

units dry for extended periods may cause the tank assembly

to warp and void the warranty.