Precautions:

1. The RAMFAN INLINE Heater was designed to be used with the UB20 utility blower and the UB20

canister with 15 or 25 ft. of duct OR with the UB20xx hazardous location blower and the UB20xx
canister with 15 or 25 ft. of duct.

2. Use with Part No’s. ED7025 or EF7025 configured as depicted above.
3. The heater will not operate properly if used with other configurations or other blowers.
4. Contact customer service for uses outside of these guidelines.

Mises en garde:

1. Le Radiateur EN CIRCUIT RAMFAN a été conçu pour être utilisé conjointement avec le ventilateur

utilitaire UB20 et le boîtier UB20 assorti de gaines de 15 ou 25 pieds (4,5 m ou 7,5 m) OU BIEN
avec le ventilateur pour locaux dangereux UB20xx et le boîtier UB20xx assorti de gaines de 15 ou
25 pieds (4,5 m ou 7,5 m).

2. Utiliser avec les Parties Nº ED7025 ou EF7025 répondant à la configuration représentée ci-dessus.
3. Le radiateur ne fonctionnera pas correctement s’il est utilisé sous d’autres configurations ou avec

d’autres ventilateurs.

4. Contacter le service à la clientèle pour toute utilisation non mentionnée dans les présentes

indications.

Setup and Operation:

1. Insert UB20 blower into the Heater air inlet and plug the UB20 into the “Switched

Power” receptacle. Ensure the UB20 blower’s “ON” / “OFF” switch, located on the side of the
UB20 is in the “ON” position.

2. Connect the Euramco Safety supplied regulator / hose assembly between the propane
tank and the Heater gas inlet.
3. Attach the UB20 Duct Canister or flexible duct to the Heater air outlet ring and fully
extend.
4. Plug the HA01 or HA02 Heater into a 115VAC power source, or the HA03 into a

240VAC power source.

5. Install Optional Thermostat: If the temperature of the space to be heated needs to be

regulated install the optional thermostat and set to highest temperature. Note: The

heater does not require the use of a thermostat to support Heater operation.

6. Open valve on propane tank.
7. Toggle the Heater switch to the “ON” position.
8. After the Heater lights up, adjust the Thermostat Temperature Setting for the desired

room temperature. The red light on the Heater switch will cycle “ON” and “OFF” with

the burner flame to regulate the room temperature.

9. Set the Heater control panel fan switch to the “ON” position if you want the UB20 blower

to run continuously during both thermostat “ON” and “OFF” cycles and after the heater

switch has been turned off.

10. Set the Heater control panel fan switch to the “AUTO” position if you want the blower to

cycle “ON” and “OFF” with the demand for heat. When the Heater switch is turned

“OFF” the fan will also turn off after the heater has cooled down.

11. If the ignition of the flame fails or the red switch light on the control panel fails to light

the cause is most likely due to a loss of airflow, propane tank is empty, or the internal over
temperature switch tripped. Examine system and remove blockage, or fill tank as necessary.
Wait for the Heater to purge for 30 to 90 seconds and attempt to re-ignite the flame. If the
Heater fails to re-ignite itself, toggle the heater switch to the “OFF” position. Unplug the heater
from its power source. Recheck all gas and electrical connection and proceed with step 4
above.