Caution, Warning – Carter-Hoffmann HWF18A1GM Manuel d'utilisation

Page 8

Advertising
background image

8

LOCATION

For proper operation and maximum performance, locate the
unit in an ambient air temperature of 70ºF (21ºC).

Avoid placement in areas near exhaust fans or where there
are active air movements.

For safe operation and maximum performance, locate the
unit at least 2” from any wall or combustible material.

Unit must be on a solid level surface.

INSTALLATION AND STARTUP

GROUNDING INSTRUCTIONS

This appliance is equipped with a cord having a grounding wire with
a grounding plug which must be plugged into an outlet that is
properly installed and grounded. In the event of an electrical short
circuit, grounding reduces the risk of electric shock by providing an
escape wire for the electric current.

WARNING—Improper use of the grounding can result in a risk
of electric shock.
Consult a qualified electrician or service agent if
the grounding instructions are not completely understood, or if doubt
exists as to whether the appliance is properly grounded.




If necessary, contact a licensed
electrician to install an appropriate
20 amp electrical circuit with correct
NEMA receptacle.

DO NOT use an extension cord.

Installation procedures must be
performed by a qualified technician
with full knowledge of all applicable
electrical codes. Failure could
result in personal injury and proper-
ty damage.

Damage to unit due to being
connected to the wrong voltage or
phase is NOT covered by warranty.

START UP

1. Prior to use, thoroughly clean the interior of the unit, per

the instructions in this manual. Familiarize yourself with
the controls.

2. Plug the power cord of the cabinet into a grounded outlet

with a electrical service according to the electrical infor-
mation provided below. DO NOT MODIFY CORD PLUG.

3. Set POWER switch to the “ON” position.

4. Do not load product into the cabinet. Allow the heat to

remove any residual oils which may adhere to inside met-
al surfaces. A slight emission of smoke is common dur-
ing the first few hours of operation.

T

he ground prong of the power

cord is part of a system designed to
protect you from electric shock in
the event of internal damage.

DO NOT cut off the large round
ground prong or twist a blade to fit
an existing receptacle.

CAUTION:

Electrical Shock Hazard

Unit is not waterproof, to avoid
electrical shock, keep unit from be-
ing submerged in water. Do not
operate if unit has been in contact
with water.

IMPORTANT:
Power cord is 8' long

IMPORTANT:
Not under warranty

WARNING:

Risk of personal injury

WARNING:

Risk of personal injury

HL1 & HL3 Models

HL2 & HL4 Models

220 volt CE international versions:

HL1 & HL3 Series: 1800 watts, 220
volts, 8.2 Amps, 50/60 Hz, single
phase

HL2 & HL4 Series: 2100 watts, 220
volts, 9.5 Amps, 50/60 Hz, single
phase

Plug cap per specific country require-
ments / standards

Canada: 1400 watts, 120 volts, 12
Amps, single phase, NEMA 5-15P

Advertising