Carter-Hoffmann HWF18A1GM Manuel d'utilisation

Page 17

Advertising
background image

17

TROUBLESHOOTING GUIDE

SYMPTOM

POSSIBLE CAUSE

SUGGESTED REMEDY

No power on display Not plugged in or circuit breaker

tripped

Check or reset circuit breaker
Connect to proper receptacle

Power cord damaged

Check - replace if required

Circuit breaker tripped

Check circuit breaker

Power switch damaged or defective

Check - replace if required

Food dries out too
quickly

Operation where product temp is too
high; food pans should be covered

Check product temps going into
holding cabinet; cover food pans

Control incorrectly set or defective

Check proper operation or calibration
of control

Internal wiring error

Call service technician

Element hi-limit trip / defective

Call service technician

Takes too long to
get to temperature

Improper voltage

Call service technician to verify
incoming voltage matches cabinet
specifications.

Unit is hot
but low or no airflow

Internal wiring error

Call service technician

Circulation motor has quit

Call service technician

Improper voltage

Call service technician to verify
incoming voltage matches cabinet
specifications.

Unit is on, motors
are running but no
heat


NOTE:


The technical content of this manual,
including any wiring diagrams, schemat-
ics, parts breakdown illustrations and /
or adjustment procedures, is intended
for use ONLY by qualified technical
personnel

.


NOTE:

For warranty service, call Carter-Hoffmann
direct at 800-323-9793 for authorization,
we will dispatch the nearest authorized
service agency.

Advertising