Whirlpool WET3300XQ Manuel d'utilisation

Page 16

Advertising
background image

16

1.

Prepare to connect neutral

ground wire and neutral wire

B

E

A

Remove center terminal block screw (B). Remove neutral

ground wire (E) from external ground conductor screw (A).

C

E

B

Connect neutral ground wire

and neutral wire

2.

Connect neutral ground wire (E) and neutral wire (white or

center wire) (C) of power supply cord or cable under center

terminal block screw (B). Tighten screw.

Connect remaining wires

3.

Place hooked ends of remaining wires under outer terminal

block screws (hooks facing right). Tighten screws.

A

G

Connect external ground wire

4.

Connect a separate copper ground wire (G) from the external

ground conductor screw (A) to an adequate ground. Finally,

reinsert tab of terminal block cover into slot of dryer rear

panel. Secure cover with hold-down screw. Now, go to

“Venting Requirements.”

Optional 3-Wire Connection

IMPORTANT: You must verify with a qualified electrician that

this grounding method is acceptable before connecting.

Connect remaining wires

4.

Place hooked ends of remaining direct wire cable wires

under outer terminal block screws (hooks facing right).

Squeeze hooked ends together and tighten screws. Finally,

reinsert tab of terminal block cover into slot of dryer rear

panel. Secure cover with hold-down screw. Now, go to

“Venting Requirements.”

B

C

Place hooked end of neutral wire (white or

center) (C) of direct wire cable under center

terminal block screw (B). Squeeze hooked

end together. Tighten screw.

3.

Connect neutral wire

Advertising