Direct wire connection – Whirlpool WET3300XQ Manuel d'utilisation

Page 14

Advertising
background image

14

4-Wire Direct Wire Connection

IMPORTANT:

A 4-wire connection is required for mobile

homes and where local codes do not permit 3-wire

connections.

2.

Prepare to connect neutral ground

wire and neutral wire

E

A

B

Remove center terminal block screw (B). Remove neutral

ground wire (E) from external ground conductor screw (A).

Unscrew the removable conduit connector (A) and any

screws from a 3/4" (19 mm) UL listed strain relief (UL marking

on strain relief). Put the threaded section of the strain relief

(C) through the hole below the terminal block opening (B).

Reaching inside the terminal block opening, screw the

removable conduit connector (A) onto the strain relief threads.

A

B

C

1.

Attach direct wire strain relief

Put direct wire cable through the strain relief. The strain

relief should have a tight fit with the dryer cabinet and be in

a horizontal position. Tighten strain relief screw against the

direct wire cable.

2.

Attach direct wire cable to strain relief

Direct Wire Strain Relief

Direct wire cable must have 5 ft. (1.52 m) of extra length so

washer/dryer may be moved if needed.

Strip 5" (127 mm) of outer covering from end of cable,

leaving bare ground wire at 5" (127 mm). Cut 1

1

/

2

" (38 mm)

from remaining 3 wires. Strip insulation back 1" (25 mm).

Shape ends of wires into hooks.

1"

(25 mm)

5"

(127 mm

)

1.

Prepare your 4-wire cable for direct

connection

Direct Wire Connection

3-wire direct connection:

Go to “3-Wire Direct Connection” on

page 15.

4-wire direct connection:

Go to “4-Wire Direct Connection” on

this page.

If your wiring looks like this:

Advertising