3-Wire Direct Wire Connection

IMPORTANT: Use where local codes permit connecting

cabinet-ground conductor to neutral wire.

B

2.

Remove center screw

Remove center terminal block screw (B).

4.

Connect ground wire

F

A

Connect ground wire (green or bare) (F) of direct wire cable

to external ground conductor screw (A). Tighten screw.

Place hooked ends of remaining direct wire cable wires

under outer terminal block screws (hooks facing right).

Squeeze hooked ends together and tighten screws. Finally,

reinsert tab of terminal block cover into slot of dryer rear

panel. Secure cover with hold-down screw. Now, go to

“Venting Requirements.”

5.

Connect remaining wires

B

E

C

3.

Connect neutral ground wire

and neutral wire

Connect neutral ground wire (E) and place

hooked end (hook facing right) of neutral

wire (white or center wire) (C) of direct

wire cable under center screw of terminal

block (B). Squeeze hooked ends together

and tighten screw.

Direct wire cable must have 5 ft. (1.52 m) of extra length so

washer/dryer may be moved if needed.

Strip 3

1

/

2

" (89 mm) of outer covering from end of cable. Strip

insulation back 1" (25 mm). If using 3-wire cable with ground

wire, cut bare wire even with outer covering. Shape wire ends

into hooks.

1"

(25 mm)

3½"

(89 mm)

1.

Prepare your 3-wire cable for

direct connection