Advanced Mode:

In the bottom right hand corner of the Zone Revolution
software there is an “Advanced” button. The features
allow the contractor to adjust DSP processing, min and
max volumes and other advanced features. This section
of the software can be password protected against
inappropriate access. To set a new password click
“Settings > Set Password”.

Out of the box the Zone Revolution does not have a
password set. A password can be added by simply
typing it into the new password box and a pop up will
inform you that the change was successful. To remove
a password simply type in the “Old password” and
then leave the new password box blank, a prompt
should appear telling you that the password has been
removed.

Advanced Mode Set Up:

At the base of the advanced mode screen, there are
four buttons added to the GUI. These allow set up of
functions relating to the Audio Setup, Control Panels,
Master Override and Presets.

Audio Setup

The Audio Setup page allows the user to control all DSP
functions of each input and output signal. The page
also allows the user to see the signal fl ow from input
to output. Within this screen there are small signal
indicators for each input and output. This page makes a
great trouble shooting guide to see signal entering and
leaving the DSP functions.