1

IEC Mains Socket

This is a standard 3-pin IEC socket (IEC3020-C14). It accepts a standard IEC
mains cable, provided. The fuse draw contains the mains fuse and a spare.
The mains fuse is a time lag (slow blow) HRC 20mm x 5mm fuse, the fuse
ratings are:

230V : 0.6A S/B

115V : 1.2A S/B

The power supply is universal so it will accept voltages from 90-264V.

2

Optional Cobranet Card

Optional module available to enable Cobranet connectivity. This card will
parallel all inputs and outputs to be available on Cobranet.

3

Override and Preset Contact Closures

Pins 1-8 are trigger pins for the global presets. When any one of these pins
are momentarily joined to the COM pin that preset will be triggered.

Pin O/Ride is a trigger for the external Master Override function. This can be
set up within the software.

4

Ethernet Port

The Ethernet port is a standard RJ45 port which allows the user control with
the supplied GUI or a third party control system.

5

RS485 Ports

The RS485 ports allow for the connection of ICON-CP control panels using
standard pin to pin wiring. Use of straight through CAT5 cable is suggested to
keep the RS485 line twisted for optimal noise rejection

6

AM Linking Ports

The AM Linking ports allow multiple Zone Revolution units to be linked for
expansion purposes.

This feature is for future use.

7

Balanced Zone Outputs

Balanced outputs for each zone are supplied on Euroblock connectors for easy
termination. These are a standard 5.08mm pitch.

8

Unbalanced Stereo Inputs

Unbalanced RCA connections are supplied for all stereo inputs. They are in
stereo pairs as the unit supports stereo straight through.

9

Balanced Mic/Line Inputs

Mic/Line inputs are supplied on Euroblock connectors for easy termination.
These are also a standard 5.08mm pitch.

10

Page Ports

The Page Ports allow for the connection of ICON Paging Stations. ICON Paging
Stations use standard pin to pin wiring. Use of straight through CAT5 cable is
suggested to keep the RS485 & Audio lines twisted for optimal noise rejection