2 chimney connection – Napoleon Fireplaces IR3G Manuel d'utilisation

Page 9

Advertising
background image

9

W415-1034 / A / 10.02.12

While the liners must be continuous from the appliance to the chimney cap, to

achieve the needed length, they may be coupled, using an approved coupler.

We recommend that exhaust vents that pass through unheated spaces,

such as tall exterior chimneys, be wrapped in a protective sleeve to minimize

condensation and reverse fl ow symptoms. See Trouble Shooting for details.

This appliance is approved for use with a 3" exhaust and air intake.

A. OUTSIDE: Slip the one end of a liner a minimum of 2" over the

sleeve of the air terminal. Secure using 3 screws. Then seal the

joint and screw heads with high temperature sealant. Repeat with

the other liner.

NOTE: We recommend that the other end of the exhaust liner be marked to eliminate the

exhaust liner being connected to the intake collar at the appliance.

B.

Gently stretch the liners to the

required lengths and insert into the

chimney. Trim and fi t the fl ashing

plate to suit the chimney termination.

Place the air terminal onto the top of

the chimney. Make weather tight by

sealing with caulking (not supplied).

Fasten to the chimney with screws

and plugs (not supplied).

C. INSIDE: Remove the securing screw

from the front of the vent mounting

assembly. Slide the vent mount

assembly from the track. Route the

fl ex liners through the slider. Attach

and secure the liners to the vent

mounting plate, ensuring that the

marked exhaust liner is attached to

the exhaust collar.

D.

The appliance may now be pushed

into the opening and the mounting

plate assembly slid back into the

track, and the securing screw started.

Once the appliance is in it's fi nal

position tighten the securing screw until the slider makes contact with the front stop.

FLASHING
PLATE

2” OVERLAP

SEALANT
HI-TEMP

INTAKE

EXHAUST

SECURING

SCREW

SLIDER

MOUNTING

PLATE

HIGH TEMP

SEALANT

2”

OVERLAP

3”

LINERS

EXHAUST

INTAKE

VENT MOUNT

ASSEMBLY

3.2 CHIMNEY

CONNECTION

Chimney installation must conform to both national and local code requirements. The chimney must be lined
with one 3" diameter liner for intake and one 3" diameter liner for exhaust. The minimum and maximum vent
lengths are 10 and 35 feet respectively. Recommended kits come in 3 lengths:

2-3" DOUBLE PLY ALUMINUM LINER-INLET AND EXHAUST:

GDI-320KT VENT KIT 20FT

GDI-325KT VENT KIT 25 FT
GDI-335KT VENT KIT 35 FT