W415-1034 /

A / 10.02.12

THERMOSTAT

OFF/ON/SMART

ROOM

TEMPERATURE

LOW BATTERY

ALARM

CHILD SAFETY

LOCK OUT

TRANSMISSION

AUX. OUTPUT

FAN

FLAME

TEMPERATURE SET POINT/ LEVEL/ STATUS

6

35.1

6.2 GENERAL TRANSMITTER LAYOUT

6.3 APPLIANCE

OPERATION

A.

Install 4 AA batteries into the receiver battery bay as indicated on the battery cover (+/-). (Only required
as back up to household electricity).

B.

Place the 3 position slider switch of the receiver in the “Remote” position.

C.

Using the end of a paper clip, or other similar object, insert the end of the paper clip into the hole
marked “PRG” on the receiver front cover. The receiver will “beep” three (3) times to indicate that it is
ready to synchronize with the transmitter.

D.

Install the 3 AAA batteries in the transmitter battery bay, located on the base of the transmitter.
With the batteries already installed in the transmitter, push the “ON” button. The receiver will “beep”
four times to indicate the transmitter’s command is accepted and set to the particular code of that
transmitter. The system is now initialized.

35.2A

6.4 HAND HELD REMOTE OPERATIONS

A.

Press the ON/OFF key on the transmitter. The transmitter
display will show all active icons on the screen. A single
“beep” from the receiver will confi rm reception of the
command.

35.4

BLUE LCD DISPLAY

ON/OFF KEY

THERMOSTAT KEY

UP/DOWN

ARROW KEY

MODE KEY