Combustible mantel clearance can vary
according to the mantel depth. Use the
graph to help evaluate the clearance
needed. These same requirements
apply to any combustibles protruding
on either side of the appliance.

H

D

F

G

MANTEL DEPTH

0” (mm)

+

(

,

*

+

7

0

$

1

7

(

/

E

C

B

A

!

WARNING

RISK OF FIRE, MAINTAIN ALL SPECIFIED AIR SPACE CLEARANCES TO COMBUSTIBLES. FAILURE

TO COMPLY WITH THESE INSTRUCTIONS MAY CAUSE A FIRE OR CAUSE THE APPLIANCE TO

OVERHEAT. ENSURE ALL CLEARANCES (I.E. BACK, SIDE, TOP, VENT, MANTEL, FRONT, ETC.) ARE

CLEARLY MAINTAINED.

WHEN USING PAINT OR LACQUER TO FINISH THE MANTEL, THE PAINT OR LACQUER MUST BE

HEAT RESISTANT TO PREVENT DISCOLOURATION.

73.1

4.1 MINIMUM MANTEL CLEARANCES

D

A

B

C

E

F

H

G

20

1

/

2

(520.7mm)

4.2 DOOR REMOVAL AND INSTALLATION

!

WARNING

GLASS MAY BE HOT, DO NOT TOUCH GLASS UNTIL COOLED.

THE DOOR LATCHES ARE PART OF A SAFETY SYSTEM AND MUST BE PROPERLY ENGAGED. DO

NOT OPERATE THE APPLIANCE WITH LATCHES DISENGAGED.

FACING AND/OR FINISHING MATERIALS MUST NOT INTERFERE WITH AIR FLOW THROUGH AIR

OPENINGS, LOUVRES OPENINGS, OPERATION OF LOUVRES OR DOORS OR ACCESS FOR

SERVICE. OBSERVE ALL CLEARANCES WHEN APPLYING COMBUSTIBLE MATERIALS.

BEFORE DOOR IS REMOVED TURN THE APPLIANCE OFF AND WAIT UNTIL APPLIANCE IS COOL TO

THE TOUCH. DOORS ARE HEAVY AND FRAGILE SO HANDLE WITH CARE.

75.1

DOOR LATCH

The optional front must be removed to allow the door to be opened or closed. Release the top left and right
door latches, located at the top of the door. Tilt forward and lift from slots.

MANTEL DIMENSIONS

Ref

Height

Ref

Depth

A

17" (431.8mm)

E

6" (152.4mm)

B

16" (406.4mm)

F

5" (127mm)

C

15" (381mm)

G

4" (101.6mm)

D

14” (355.6mm)

H

3" (76.2mm)