Napoleon Fireplaces High Country 3000 - NZ3000 Manuel d'utilisation

Page 30

Advertising
background image

W415-0711 / D / 05.09.13

30

EN

INSTALL THE KB35 AND
BY-PASS SWITCHES IN A
CONVENIENT LOCATION

FAN

L2

L1

THERMODISC

G

FAN-SPEED CONTROL

(RHEOSTAT {VARIABLE SPEED SWITCH})

or WALL SWITCH or THERMOSTAT

NOT SUPPLIED

BY-PASS

(SUMMER)

SWITCH

NOT SUPPLIED

PRESSURE

SWITCH

GRILL

FILTER

ALLOW FOR
THICKNESS
OF FINISHING
MATERIAL

One black wire
- connects to power "L2"
(neutral lead).

One green wire
- connects to ground.

One white wire
- connects to the fan-
speed control, rheostat, or
wall switch,or thermostat.

VENT CONNECTION
D.

Connect the 6”(152.4mm) liner to the 6"(152.4mm) appliance collar and blower collars. Secure using
3 screws on each end and seal with caulking. Liner stretches to a maximum of 10’(3m).

GRILL AND FILTER INSTALLATION
E.
Insert

the

fi lter into the grill. Foam gasket (

1

/

2

”(12.7mm) weather stripping) between the grill and

blower housing is recommended, but not supplied. The blower fi lter is washable. The bottom lip of
the grill latches over the bottom lip of the housing. Use two screws to secure the top of the grill to the
facing.

NOTE: FOR COMPLETE INSTALLATION INSTRUCTIONS REFER TO THE BLOWER KIT.