W415-0711 / D / 05.09.13

22

EN

6.0 FINISHING

40”

(1016MM)

55 1/2”

(1409.7MM)

7 3/4” (196.8MM) MIN CEMENT

BOARD FROM THE SIDE OF

THE UNIT TO COMBUSTIBLES

7 3/4”

(196.8MM)

MIN

DRYWALL

NON-COMBUSTIBLE
MATERIAL

FACE MUST

HAVE A

MINIMUM

84”(2133.6MM)

HEIGHT OF

CEMENT BOARD

DEPENDING

UPON CEILING

HEIGHT

COMBUSTIBLE

FACING AND

WOOD FRAMING

MAY START AT

84”(2133.6MM)

ABOVE THE

BASE OF THE

UNIT

EMBER STRIP

NOTE: JOINT
COMPOUNDS AND
TAPES THAT ARE
RESILIENT TO HEAT
AND CRACKING
SHOULD BE USED
WHEN TAPING AND
MUDDING SEAMS.

!

WARNING

VENTILATION OPENINGS ARE REQUIRED IN ENCLOSURES UP TO 96" HIGH. THEY ARE

RECOMMENDED FOR ALL ENCLOSURES. ABOVE 84" COMBUSTIBLE FINISHING MATERIALS MAY

BE USED ON THE FRONT FACE.

The appliance is shipped with a template that is 1/8" (3.2mm) larger on the
top, bottom and each side than the faceplate. Leave the template in place
when installing the fi nishing material to insure the faceplate will fi t inside the
fi nishing material edging..

TEMPLATE

USE ONLY A NON-COMBUSTIBLE MATERIAL TO FINISH THE FACE OF THE APPLIANCE. A NON-

COMBUSTIBLE MATERIAL SUCH AS CEMENT BOARD IS REQUIRED FOR THIS PURPOSE.

DO NOT INSULATE AROUND THE APPLIANCE.

NOTE: A ventilated enclosure
is recommended. See
"VENTILATION OPENINGS"
section.