Napoleon Fireplaces High Country 3000 - NZ3000 Manuel d'utilisation

Page 20

Advertising
background image

W415-0711 / D / 05.09.13

20

EN

29

1

/

2

(749.3MM)

42” (1066.8MM)

6” (152.4MM)

MIN

6” (152.4MM)

MIN

NOTE: When constructing the enclosure allow
for fi nishing material thickness to maintain
clearances.

A minimum of 6" is required to combustibles from the
side of the appliance.

54” (1371.6MM)

42” (1066.8MM)

6”

(152.4MM)

MIN

6”

(152.4MM)

MIN

29

1

/

2

(749.3MM)

42” (1066.8MM)

54” (1371.6MM)

75

5

/

16

(1913MM)

106

1

/

2

(2552.7MM)

Objects placed in front of the appliance must be kept a minimum of 48" (1219.2mm) away from the front of the
appliance.

MAINTAIN THESE MINIMUM CLEARANCES TO COMBUSTIBLES:
Framed Enclosure
:
Rear

-

0"

to

stand-offs

Sides

-

6"

(152.4mm)

Ceiling (Enclosure)

- 84" (2133.6mm) from the base of the appliance

Ceiling (Room)

- 84" (2133.6mm) from the base of the appliance

Chimney

- 2" (50.8mm)

Hot Air Gravity Ductwork Insulation

- 1" (25.4mm)

5.1 CLEARANCE TO COMBUSTIBLES

5.2 MINIMUM ENCLOSURE CLEARANCES