1 ventilation openings – Napoleon Fireplaces High Country 3000 - NZ3000 Manuel d'utilisation

Page 23

Advertising
background image

W415-0711 / D / 05.09.13

23

EN

1”(25.4MM)

OPEN

1”(25.4MM)

OPEN

84”(2133.6MM) MIN.

ENCLOSURE

HEIGHT

VENTILATION

REQUIRED IN

ENCLOSURES

BETWEEN

84”(2133.6MM)

AND 96”(2438.4MM)

NOTE: As an alternate to grates a 1" x 40" (25.4mm
x 1016mm )wide gap can be left in the bottom and
top of any fi nishing material to circulate the air
from the fl oor, around the appliance and out the
top.

6.1 VENTILATION

OPENINGS

12” (304.8MM)

MAXIMUM

12” (304.8MM)

MAXIMUM

MINIMUM 40 SQUARE INCHES (1016MM) OF
VENTILATION OPENING REQUIRED, BOTH AT
THE TOP AND BOTTOM OF THE ENCLOSURE.

84”(2133.6MM) MIN.

ENCLOSURE

HEIGHT

VENTILATION

REQUIRED IN

ENCLOSURES

BETWEEN

84”(2133.6MM)

AND 96”

(2438.4MM)