Napoleon Fireplaces Grandville 42 - BGD42 Manuel d'utilisation

Page 28

Advertising
background image

W415-0777 / E / 08.26.13

28

EN

41"

1041mm

42 1/2"

1080mm58"

1473mm

OUTSIDE

CHASE

42 1/2"

1080mm

22 1/4"

565mm

22 1/4"

565mm

42 1/2"

1080mm

6"

SIDE

WALL

INSIDE

CHASE

Minimum clearance to combustible construction from appliance and vent surfaces:
Sides, back, bottom and top of the unit

0"

Recessed depth

22" (559mm)

All around the vent pipe*

2" (51mm)

Enclosure top

45 1/2" (1156mm)

Ceiling

54" (1372mm) from bottom of unit

*HORIZONTAL VENT SECTIONS:

A minimum clearance of 2" (51mm) all around the vent pipe on all horizontal runs

to combustibles is required. Use fi restop spacer W010-2116 (supplied).

*VERTICAL VENT SECTIONS:

A minimum of 1" (25mm) all around the vent pipe on all vertical runs to combustibles

is required except for clearances in appliance enclosures. Use fi restop spacer W500-0367 (not supplied).

It is best to frame your appliance after it is positioned and the vent system is installed. Use 2x4's and frame to local
building codes. It is not necessary to install a hearth extension with this appliance system.

When roughing in the appliance, raise the appliance to accommodate for the thickness of the fi nished fl oor materials,
i.e. tile, carpeting, hard wood, which if not planned for will interfere with the opening of the lower access door and the
installation of many decorative fl ashing accessories.

Combustible materials may be installed fl ush with the front of the appliance but must not cover or protrude past any
of the black face-areas of the appliance. Non-combustible material (brick, stone or ceramic tile) may protrude in these
areas.

5.1 MINIMUM CLEARANCE TO COMBUSTIBLES