This application occurs when venting through an exterior wall. Having
determined the correct height for the air terminal location, cut and
frame a hole in the exterior wall as illustrated to accommodate
the fi restop assembly.

The length of the vent shield may be cut shorter for
combustible walls that are less than 8 1/2” (215.9mm)
thick but the vent shield must extend the full depth of
the combustible wall.

A.

Apply a bead of caulking (not supplied) all around and

place the fi restop top, so that the vent shield covers the
top of the vent within the opening.

B.

Place the fi restop bottom against the fi restop top and secure the

two together. Adjust the assembly to ensure it is tight to

the vent. Secure fi restop to wall. This restricts cold air

from being drawn into the room or around the

appliance. Ensure that both spacer and shield

maintain the required clearance to

combustibles. Once the vent pipe is

installed in its fi nal position, apply

sealant W573-0002 (not supplied)

between the vent pipe and the fi restop

spacer as illustrated.

DETERMINE
THE
CORRECT
HEIGHT

FIRESTOP

SPACER

FINISHING
MATERIAL

CAULKING

CAULKING

20.3A

VENT

SHIELD

FIRESTOP

BOTTOM

FIRESTOP

TOP

!

WARNING

THE FIRESTOP ASSEMBLY MUST BE INSTALLED WITH THE VENT SHIELD TO THE TOP.

TERMINALS MUST NOT BE RECESSED INTO A WALL OR SIDING MORE THAN THE DEPTH OF THE

RETURN FLANGE OF THE MOUNTING PLATE.

4.1.1 HORIZONTAL INSTALLATION