E-7

GUIDE DE DÉPANNAGE

E-7

IDEALARC® DC-1000

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your
Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.

CAUTION

Respecter toutes les Consignes de Sécurité détaillées tout au long de ce manuel

If troubleshooting guide indicates a possible P.C. board problem, the following guide can be used to locate the problem.

LA MACHINE A UNE SORTIE

(Cavalier 2-4) MAIS SE

DÉCLENCHE IMMÉDIATEMENT

VÉRIFIER QUʼIL NʼY AIT

VÉRIFIER LE RACCORDEMENT

PAS DE COURT-CIRCUIT ENTRE

À TERRE SUR TERMINALE

LES FILS DE TRAVAIL ET DʼÉLECTRODE,

DE SORTIE NÉGATIVE

RETIRER LES FILS EXTERNES

73, 74, 75, 76, 77

DES TERMINALES DE SORTIE

SI LE PROBLÈME PERSISTE,

VÉRIFIER LE LED3 SUR LE

TABLEAU DE CONTRÔLE

SI LA LUMIÈRE SʼALLUME

PUIS SʼÉTEINT VITE LORSQUʼON

APPUIE SUR LE BOUTON DE

DÉMARRAGE, LE TABLEAU DE

CONTRÔLE EST DÉFECTUEUX

ET DOIT ÊTRE CHANGÉ

SOUDAGE ERRATIQUE

VÉRIFIER LA PROCÉDURE

VÉRIFIER QUE LA POSITION DE LʼINTER-

RUPTEUR DE MODE SOIT APPROPRIÉE

POUR LE PROCÉDÉ UTILISÉ

VÉRIFIER QUE LES LEDS 1 À 6

BRILLENT DE FAÇON IDENTIQUE

SI LES LUMIÈRES NE SONT PAS TOUTES

PLUS OU MOINS AUSSI BRILLANTES,

CHANGERLE TABLEAU DE CIRCUITS

IMPRIMÉS DʼALLUMAGE

PAS DE SORTIE DE LA SOUDEUSE (CONTACTEUR DʼENTRÉE « ALLUMÉ », 2 ET 4 FERMÉS)

VÉRIFIER LE LED5 DU TABLEAU DE CONTRÔLE

SI ÉTEINT

VÉRIFIER LE LED1

SI ALLUMÉ

VÉRIFIER LES LEDS DU TABLEAU

DʼALLUMAGE

LES 9 LUMIÈRES

DOIVEN

TÊTRE

ALLUMÉES

SI ÉTEINT

SI ALLUMÉ

VÉRIFIER ENTRÉE

CHANGER

C.A. VERS TABLEAU -

TABLEAU DE

TRANSFORMATEUR T2

CONTRÔLE

POSSIBLEMENT

DÉFECTUEUX

SI OUI

SI NON

VÉRIFIER LES CONNEXIONS

VÉRIFIER LES LUMIÈRES

DUFIL DE MAINTIEN

7,8,9

SUR LE SCR

SI UNE OU

SI ALLUMÉES

PLUS SONT

ET DʼAUTRES

ÉTEINTES

ALLUMÉES

VÉRIFIERENTRÉE C.A.

À TABLEAU,

CHANGER

203-204, 205-206

TABLEAU

207-208 -- POSSIBILITÉ

DʼALLUMAGE

DE BOBINAGE

AUXILIAIRE

DÉFECTUEUX SUR

TRANSFORMATEUR

PRINCIPAL

VÉRIFIER QUʼIL NʼY

AIT PAS DʼOUVERTURE

SUR LES FILS 203, 204,

205, 206, 207, 208