THERMOSTAT OPERATION


The BLAZE 1000 D/G can be operated with a thermostat control.

An optional heatstat is available for temperature control for the space being heated. To connect the heatstat, simply
plug the heatstat into an extension cord and the extension cord into the outlet marked “REMOTE STAT”. Make sure
selector is in the “STAT ON” position. Place the heatstat into the space that is being heated. The unit will now shut
down at the heatstat fixed temperature setting.

NOTE: The heatstat is available with different fixed temperature settings.

An optional 120V adjustable setting thermostat is also available.

CHANGING BURNERS ON THE BLAZE 1000 D/G



1.) MAKE SURE “MAIN SWITCH” IS IN “OFF” POSITION AND DISCONNECT MAIN POWER
SUPPLY.
2.) IF BECKETT CF800 OIL BURNER IS CURRENTLY INSTALLED AND GAS OPERATION WITH
THE CG10A IS DESIRED DISCONNECT FUEL LINE AT BURNER PUMP “INLET” AND
DISCONNECT FUEL LINE FROM “RETURN” PORT ON BURNER PUMP.
3.) DISASSEMBLE FILTER BRACKET AND FILTER ENTIRELY FROM BURNER COMPARTMENT.
4.) DISCONNECT WIRE HARNESS.
5.) REMOVE THE (4) 5/16” NUTS HOLDING THE BURNER.
6.) REMOVE ENTIRE BECKETT CF800.
7.) MOUNT CG10A TO (4) 5/16” BOLTS (WITH GAS TRAIN CONNECTED) AND FASTEN (4) 5/16”
NUTS.
8.) FASTEN GAS TRAIN SUPPORT BRACKET TO INLET SIDE OF TRAIN.
9.) CONNECT WIRE HARNESS.
10.) SWITCH FROM “OIL” TO “GAS” ON THE MAIN CONTROL PANEL.

REVERSE THE ABOVE STEPS FOR GAS TO OIL OPERATION.