CAMPO EQUIPMENT CO. LTD. (ECOBLAZE)

6 Carson Court, Brampton, ON, CANADA, L6T 4P8

Tel: (905) 793-2525 | Fax: (905) 793-8768 | www.campoequipment.com

1.) PRESS AND HOLD THE RED BUTTON ON THE BECKETT GENISYS CONTROLLER LOCATED ON THE

CONTROL PANEL FOR 3 SECONDS TO RESET.

1.) CHECK FUEL LEVEL, FILTER, NOZZLE AND SUCTION TUBING.
2.) ENSURE PROPER POWER SUPPLY AND WIRE GAUGE IS BEING USED.
3.) IF HEATER FAILS TO IGNITE AFTER 3 ATTEMPTS, CALL YOUR SUPPLIER FOR SERVICE.

NOTE: IF UNIT HAS BEEN RESET A NUMBER OF TIMES WITHOUT IGNITION -- DO NOT ATTEMPT TO START

THE HEATER: CONTACT A QUALIFIED SERVICE TECHNICIAN.

NOTE: IN OIL OPERATION IF UNIT HAS BEEN RESET A NUMBER OF TIMES WITHOUT IGNITION THERE WILL

BE AN ACCUMULATION OF OIL IN THE COMBUSTION CHAMBER! DO NOT ATTEMPT TO START THE
HEATER: CONTACT A QUALIFIED SERVICE TECHNICIAN.

CAUTION

1.) DO NOT SHUT OFF BY DISCONNECTING SUPPLY CORD. THE HEAT EXCHANGER SHOULD BE

PROPERLY COOLED BEFORE POWER SHUTDOWN.

2.) ALWAYS MAINTAIN ADEQUATE FUEL SUPPLY.
3.) DO NOT PLUG ANYTHING OTHER THAN THE THERMOSTAT INTO THE “REMOTE STAT” PLUG.
4.) FOLLOW ELECTRICAL REQUIREMENTS SHOWN ON RATING PLATE AND/OR ELECTRICAL

REQUIREMENTS SECTION OF THIS MANUAL.

5.) DO NOT START THE HEATER WHEN EXCESS OIL HAS ACCUMULATED IN CHAMBER.
6.) DO NOT FILL TANK WHILE UNIT IS OPERATING.
7.) IN NO CASE SHOULD POWER CABLES BE SMALLER THAN WHAT IS STIPULATED ON NAMEPLATE

AND INSTRUCTION MANUAL.

8.) DO NOT USE GASOLINE, CRANKCASE OIL OR HEAVIER THAN NO. 2 FURNACE OIL.
9.) DO NOT START THE HEATER WHEN THE CHAMBER IS HOT
10.) DO NOT FILL THE TANK WHILE THE UNIT IS OPERATING
11.) DO NOT TAMPER WITH THE UNIT. HAVE A COMPETENT SERVICE-MAN MAKE ANY ADJUSTMENTS
12.) MAX OUTLET TEMPERATURE (U.S./CA) 250F/290F
13.) AT INSTALLATION ELEVATIONS ABOVE 2000 FT (610m), THE APPLIANCE SHALL BE DERATED 4

PERCENT FOR EACH 1000 FT (305m) OF ELEVATION ABOVE SEE LEVEL

14.) DO NOT USE THIS UTILITY HEATER IF ANY PART HAS BEEN UNDER WATER. IMMEDIATELY CALL A

QUALIFIED SERVICE TECHNICIAN TO INSPECT THE HEATER AND REPLACE ANY CONTROL WHICH
HAS BEEN UNDER WATER.

ELECTRICAL REQUIREMENTS: 20 AMPS


INSTALLATION INSTRUCTIONS

1.) The recommendations of local authorities having jurisdiction must be followed. For

recommended installation practices refer to C.S.A. standard B139. (CANADA)

2.) When firing the unit in an enclosed area allow 1 square inch per thousand BTU’s (refer to

C.S.A. B139) to allow the free entry of the air required for operation.

3.) For electrical supply:

120 Volts 20 amps

4.) Do not operate the unit in partly ventilated areas without a flue pipe or in close proximity to

combustible surfaces or materials.

NOTE: Installation clearances are as follows:

TOP

2 inches