Connecting to an external fuel tank (blaze 600 d), Electrical – CAMPO EQUIPMENT BLAZE 600 D Manuel d'utilisation

Page 6

Advertising
background image

CAMPO EQUIPMENT CO. LTD. (ECOBLAZE)

6 Carson Court, Brampton, ON, CANADA, L6T 4P8

Tel: (905) 793-2525 | Fax: (905) 793-8768 | www.campoequipment.com


CONNECTING TO

AN

EXTERNAL FUEL

TANK

(BLAZE 600 D)

Beckett CF800 is fitted

with 3/8” SAE male

fittings and is set up for a

2 line system to eliminate

priming. Ensure fuel tank

has an supply line and a

return line and connect

the supply line to the 3/8”

SAE fitting on the inlet

side of the fuel filter and

the return line to the

return fitting located on

the Beckett Burner pump.

For a 1 line system

remove bypass plug located on inlet port of Beckett Pump and just connect fuel line to inlet side of
fuel filter.

ELECTRICAL

WARNING: ELECTRICAL GROUNDING INSTRUCTIONS

THIS APPLIANCE IS ABLE IS TO RECEIVE 1 PHASE

120V SUPPLY MUST BE AVAILABLE.

INSTALLATION
10/3 upto 100ft

NOTE: IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE APPLIANCE MUST BE
REPLACED, IT MUST BE REPLACED WITH TYPE TEW 14GA WIRE OR ITS EQUIVALENT.


ELECTRICAL SYSTEM

BLAZE
600 D

Volts-Hertz-Phase

120-60-1

Full Load (Amps) (1PH)

17

Max fuse size (Amps) (1PH)
with time delay

20


The electrical grounding of the heater shall be in compliance with the National Electrical Code, ANSI/NFPA
70, or the CSA C22.1, Canadian Electrical Code, Part I


Head Setting

1

Air Setting (Beckett-
Shutter/Band))

3/0

APPROVAL AGENCY

OMNI

DRY WEIGHT (lbs)

700

Dimensions

70" X 26" X 61" 

 

FLUE SIZE

6”