Warning, Pressure regulator location, Oven shutoff valve – Amana ARG7302 Manuel d'utilisation

Page 8: Converting for use with natural gas or propane gas

Advertising
background image

8

Pressure Regulator Location

Remove rear cover to expose pressure regulator.

Regulator Cover

Oven Shutoff Valve

Gas valve to oven is turned on at factory, but could
accidently be turned off during installation. Verify valve is
turned on.

H

R

A A

G

H

R

A A

G

On

Off

Check Oven Shutoof Valve

Converting for Use with Natural Gas or
Propane Gas

This range arrives from factory adjusted for use with
natural gas. If using LP/propane gas is desired, range
must be converted. See “Type 1” or “Type 2” regulator.

WARNING

!

To avoid electric shock that can cause personal injury
or death, disconnect main electrical supply to range
before servicing.

Converting Type 1 Pressure Regulator for Use with
LP/ Propane
1.

Remove pressure regulator cap with a wrench.

2.

Remove plastic insert from pressure regulator cap.
• Plastic insert fits tightly in cap.

3.

Reverse plastic insert and carefully push plastic
insert firmly into hole in pressure regulator cap.
• Cap must show “LPG10” or “LP10”.

A

B

C

A—Cap
B—Plastic Insert (LP setting)
C—Spring Location

Type 1 Pressure Regulator

4.

Place pressure regulator cap on pressure regulator
and tighten.
• Insert should not disturb spring in body of regulator.

Advertising