Table 17. Submenus under the Mass Storage Controller Configuration

Item

Option

Description

SATA Configuration

Disabled / [Enabled]

Enable or disable the integrated SATA
controller.

Configure SATA as

[IDE] / RAID

To select the hard disk drive mode.
If this option is set to IDE, all the
SATA connectors will be configured
as stand-alone SATA connectors.

Notes:

1. The settings in [ ] are the default settings in the Setup Utility program.

2. The SATA Configuration item might not apply because your server came with an integrated SAS controller.

Table 18. Submenus under the SuperIO Configuration

Item

Option

Description

Serial Port1 Address

Disabled / [3F8/IRQ4] / 3E8/IRQ4 /
2E8/IRQ3

Select the I/O base address and
interrupt for serial port 1.

Serial Port2 Address

Disabled / [2F8/IRQ3] / 3E8/IRQ4 /
2E8/IRQ3

Select the I/O base address and
interrupt for serial port 2.

Note: The settings in [ ] are the default settings in the Setup Utility program.

Table 19. Submenus under the USB Configuration

Item

Option

Description

Legacy USB Support

Disabled / [Enabled] / Auto

Enable or disable the support on
legacy USB devices.

USB 2.0 Controller Mode

FullSpeed / [HiSpeed]

Select the USB speed.

Hotplug USB FDD Support

Disabled / Enabled / [Auto]

Enable or disable the support on the
hot-swap USB diskette drive.

Note: The settings in [ ] are the default settings in the Setup Utility program.

For external USB devices, the USB Mass Storage Device Configuration submenu is as below:

Emulation Type

[Auto] / Floppy / Forced FDD / Hard
Disk / CDROM

Select the type of the USB device.

Table 20. Submenus under the Hardware Health Configuration

Item

Option

Description

Items and options with BMC configuration:

Auto Fan Control

Disabled / [Enabled]

If this option is set to Disabled, the
fan runs at the full speed; if this option
is set to Enabled, the fan speed is
controlled by the system temperature.

PWM Minimal Duty Cycle

[60% Duty Cycle] / 45% Duty Cycle
/ 30% Duty Cycle

Select the PWM Minimal Duty Cycle
for the fan: 60%-100%, 45%-100%,
or 30%-100%.

Sensor Data Register Monitoring

Read Only

The sensor data in this option is for
read only. The detected data includes
the temperature, voltage and fan
speed.

Items and options without BMC configuration: