MAIN TRANSFORMER TEST (CONTINUED)

Board.
a.

Turn the machine OFF between
each test.

b.

Carefully insert the meter
probes into the back of each
Molex Plug pin cavity to perform
the test.
G2803:

c.

If any of the voltages tested are
incorrect, check for loose or bro-
ken leads between the test
points and the main transformer.

d.

If ALL the voltages tested are
incorrect or missing, go to Step
12.

12. Test for correct nameplate input volt-

age between the H1 lead at the
ON/OFF POWER SWITCH to H2 or
H3 (H5 if connected for 575 VAC) at
the reconnect panel. Voltage tested
will vary depending on Input Voltage
Connection. See wiring diagram for
test point locations.

a.

If the voltage test is incorrect,

- check for loose or broken
leads between the reconnect
panel and the ON/OFF POWER
SWITCH.

- test the ON/OFF POWER
SWITCH for proper operation.

b.

If the correct nameplate voltage
is being applied to the main
transformer and one or more of
the secondary voltages are
missing or are incorrect, the
main transformer may be faulty.
Replace.

4.

Locate the following leads on Plug
J3:
G2803:

5.

Connect main input power to the
machine.

6.

Turn the Wire-Matic 255 ON/OFF
POWER SWITCH to ON.

7.

Make the following voltage tests at
Plug J3.

a.

Turn the machine OFF between
each test.

b.

Carefully insert the meter
probes into the back of each
Molex Plug pin cavity to perform
the test.

G2803:

8.

Turn OFF the machine

9.

Locate the following leads on Plug
J6 on the G2803 Control PC Board.
G2803:

PLUG

LOCATION

1J3
3J3
2J3

LEAD

#202
#203

#204 A

FROM

LEAD

#202

(1J3)

#202

(1J3)

#203

(3J3)

TO

LEAD

#203

(3J3)

#204 A

(2J3)

#204 A

(2J3)

EXPECTED

VOLTAGE

30 VAC

15 VAC

15 VAC

PLUG

LOCATION

4J6

16J6

7J6

LEAD

#206
#208
#209

FROM

LEAD

#208

(16J6)

#208

(16J6)

#209

(7J6)

TO

LEAD

#209

(7J6)

#206

(4J6)

#206

(4J6)

EXPECTED

VOLTAGE

60 VAC

30 VAC

30 VAC

10. Turn ON the machine.