3. sequence of operation – Hobart Welding Products AIRFORCE OM-279 Manuel d'utilisation

Page 20

Advertising
background image

OM-279 Page 16

3-3.

Sequence Of Operation

Put On Personal

Safety

Equipment

After cutting arc starts, slowly

start moving torch across metal.

Adjust torch speed so

sparks go thru metal and

out bottom of cut.

Pause briefly at end of

cut before releasing trigger.

Install &

Connect

Equipment

EXAMPLE Of Cutting Operation

ST-801 400-A

Press trigger. Pilot arc starts.

Postflow continues for approx. 20 to

30 seconds after releasing trigger;

cutting arc can be instantly

restarted during postflow by

pressing trigger.

Check Torch Tip,

Electrode, And

Retaining Cup

Check Gas/Air

Pressure

Set

Controls

Begin

Cutting

Turn On

Power Source

The pilot arc starts immediately when
trigger is pressed.

Place drag shield on edge of metal,

or allow correct standoff distance –

approximately 1/8 in (3 mm).

Do not clean torch by hitting it against a
hard surface. Hitting hard surfaces can
damage torch parts and stop proper opera-
tion.

Inspect shield cup, tip, and electrode for
wear before cutting or whenever cutting
speed has been significantly reduced (see
torch Owner’s Manual). Do not operate
torch without a tip or electrode in place.