SECTION 3 – OPERATION

3-1.

Front Panel Controls

1

Pilot Arc Switch

Use switch to control pilot arc.

Place switch in Expanded Metal position for
continuous pilot arc. Use while cutting ex-
panded metals only.

.

The Expanded Metal position keeps the
pilot arc in the circuit at all times. Life of
consumables will be significantly re-
duced while in Expanded Metal mode.

Place switch in Tip Saver position to provide
pilot arc output for arc starting only. Use Tip

Saver position in most applications to length-
en the life of the torch and its consumables,
and to obtain maximum cutting performance.

Torch trigger must be reset after every cut
while in Tip Saver mode.

2

Gas/Air Pressure Gauge

3

Output Control

Use control to select cutting output in am-
peres. Gas/air automatically flows at the set
pressure.

Use Gas/Air Set area of control range for set-
ting gas/air pressure (see Section 3-2).

4

Trouble Lights (see Section 4-2)

5

Ready Light

Ready light comes On when unit is On to indi-
cate that all safety shutdown systems are
okay. If Ready light does not come On, check
trouble lights.

6

Power Light

7

Power Switch

1

Ref. ST-190 676

3

4

5

6

7

2

Advertising