OM-474 Page 26

7-3.

Servicing Air Cleaner

aircleaner2 4/96 – ST-153 929-B / ST-153 585 / Ref. ST-191 898 / Ref. S-0698-B

Y

Stop engine.

1

Intake Manifold

2

Service Indicator

3

Window

4

Reset Button

Service air cleaner element if red
band appears in window. A green
band means air cleaner is okay.
Press button to reset indicator.

Y

Do not run engine without air
cleaner or with dirty element.

Clean or replace element if dirty or
damaged. Replace element yearly
or after six cleanings.

5

Dust Cap

6

Baffle

7

Element

8

Plastic Fins

9

Housing

To Clean air filter:

Wipe off cap and housing. Remove
cap and dump out dust. Wipe dust
from inside cap and housing with
damp cloth. Remove element and
reinstall cap.

Y

Do not clean housing with air
hose.

Clean element with compressed air
only. Keep nozzle at least 1 in (25
mm) from inside of element. Max. air
pressure: 100 psi (690 kPa). Do not
remove plastic fins. Replace ele-
ment if it has holes or damaged
gaskets.

Reinstall element and cap (cap
arrows pointing up).

2