1. installing welding generator, 2. connecting the battery – Hobart Welding Products CONTRACTOR 40D OM-474 Manuel d'utilisation
Page 18

OM-474 Page 14
SECTION 4 – INSTALLATION
4-1.
Installing Welding Generator
install1 12/99 – Ref. ST-800 652 / Ref. ST-800 477-A / ST-158 936-A / S-0854
1
2
Electrically bond generator frame to
vehicle frame by metal-to-metal
contact.
GND/PE
3
4
Y
Always ground generator
frame to vehicle frame to pre-
vent electric shock and static
electricity hazards.
1
Generator Base
2
Metal Vehicle Frame
3
Equipment Grounding
Terminal
4
Grounding Cable
Use #10 AWG or larger insulated
copper wire.
Y
If unit does not have GFCI re-
ceptacles, use GFCI-
protected extension cord.
2
OR
18 in
(460 mm)
18 in
(460 mm)
18 in
(460 mm)
18 in
(460 mm)
18 in
(460 mm)
OR
Movement
Airflow Clearance
Location
Grounding
OR
Y
Do Not Lift Unit From End
4-2.
Connecting The Battery
ST-154 863-B / Ref. ST-191 898 / Ref. S-0756-C
1/2 in
–
+
Y
Connect (–) Cable Last.
Tools Needed: